File containing the class for CDAQ to NiDAQ drivers.
"""
import numpy as np
import warnings
from brainspy.processors.hardware.drivers.ni.setup import (
NationalInstrumentsSetup,
SYNCHRONISATION_VALUE,
CDAQ_TO_NIDAQ_RAMPING_TIME_SECONDS,
)
[docs]
class CDAQtoNiDAQ(NationalInstrumentsSetup):
"""
Class to establish a connection (for a single, or multiple hardware DNPUs) with the CDAQtoNiDAQ
national instrument. It requires an additional channel to send a spike
from the CDAQ to the NIDAQ. The data is offsetted to let the NIDAQ read the spike and start
synchronising after receiving it.
"""
def __init__(self, configs):
"""
Initialize the hardware processor. No trigger source required for this device.
Parameters
----------
configs : dict
Key-value pairs required in the configs dictionary to initialise the driver. These are
described in the parent class
brainspy.processors.hardware.drivers.ni.setup.NationalInstrumentsSetup.
Appart from the values described there, there are some internal keys that are added
internally in this class during the initialisation. None of these are required to
be passed on the configs.
auto_start : bool
If the task is not explicitly started with the DAQmx start_task method, it will
start it anyway. This value is set to True for this setup.
offset : int
Value (in milliseconds) that the original
activation voltage will be displaced, in order to enable the spiking signal to
reach the nidaq setup. The default value is the SYNCHRONISATION_VALUE multiplied
by the activation instrument sampling frequency.
max_ramping_time_seconds : int
To set the ramp time for the setup. It is defined with the flags
CDAQ_TO_CDAQ_RAMPING_TIME_SECONDS in
brainspy/processors/hardware/drivers/ni/setup.py. Do not tamper with it,
as it could disable security checks designed to avoid breaking devices.
"""
if configs['instruments_setup'][
'average_io_point_difference'] is not True:
raise AssertionError(
"The average_io_point_difference flag can only be true for cdaq to nidaq setups"
)
assert len(configs["instruments_setup"]["activation_channels"]) == len(
configs["instruments_setup"]["activation_voltage_ranges"])
warn = False
for voltage_range in configs["instruments_setup"][
"activation_voltage_ranges"]:
if (voltage_range[0] < -1.2 or voltage_range[1] > 1):
warn = True
if warn is True:
warnings.warn(
" Device maybe damaged, Voltage range below -1.2 or above 1")
if configs["instruments_setup"]["average_io_point_difference"] is False:
raise AssertionError(
"average_io_point_difference should be set to True for Nidaq driver"
)
configs["auto_start"] = False
# The offset specifies the number of zero points that will be added to the
# beginning of the signal, so that it gives time to the instrument to read
configs["offset"] = int(
configs["instruments_setup"]["activation_sampling_frequency"] *
SYNCHRONISATION_VALUE)
configs[
"max_ramping_time_seconds"] = CDAQ_TO_NIDAQ_RAMPING_TIME_SECONDS
super().__init__(configs)
self.tasks_driver.add_synchronisation_channels(
self.configs["instruments_setup"]["readout_instrument"],
self.configs["instruments_setup"]["activation_instrument"],
)
[docs]
def forward_numpy(self, y):
"""
The forward function computes output numpy values from input numpy array.
This is done to enable compatibility of the the model with numpy
The first point of the read_data does not perform a reading.
To synchronise it with the original signal, a point is added at the original signal y.
The signal read in 'data' discards the first point.
Parameters
----------
y : np.array
Input data matrix to be sent to the device.
The data should have a shape of: (device_input_channel_no, data_point_no)
Where device_input_channel_no is typically the number of activation
electrodes of the DNPU.
Returns
-------
np.array
Output data that has been read from the device when receiving the input y.
"""
assert type(
y) == np.ndarray, "Input data should be of type - numpy array"
self.original_shape = y.shape[0]
y = y.T
# assert (self.configs["data"]["shape"] == y.shape[1]
# ), f"configs value with key 'shape' must be {y.shape[1]}"
y = self.synchronise_input_data(y)
max_attempts = 5
attempts = 1
finished = False
while not finished and (attempts < max_attempts):
data, finished = self.readout_trial(y)
attempts += 1
data *= self.inversion
assert finished, (
"Error: unable to synchronise input and output. Output: " +
str(data.shape[1]) + " points.")
return data.T
[docs]
def readout_trial(self, y):
"""
Attempts to perform a readout from the device given an input array.
Reads the data, processes it and synchronises the output with regard
to the input data.
Parameters
----------
y : np.array
Input data matrix to be sent to the device.
The data should have a shape of: (device_input_channel_no, data_point_no)
Where device_input_channel_no is typically the number of activation
electrodes of the DNPU.
Returns
-------
np.array,bool
Synchronised output data from the device and wheather the readout is complete
"""
assert type(
y) == np.ndarray, "input data should be of type - numpy-array"
data = self.read_data(y)
data = self.process_output_data(data)
data = self.average_point_difference(data)
data, cut_value_is_zero = self.synchronise_output_data(data)
# Perform checks to determine if the measurement trial was successful
# or not (finished).
if self.io_point_difference == 1 or self.configs['instruments_setup'][
'average_io_point_difference']:
finished = data.shape[1] == self.original_shape
else:
finished = data.shape[
1] == self.original_shape * self.io_point_difference
return data, finished and not cut_value_is_zero
[docs]
def get_output_cut_value(self, read_data):
"""
The input signal is synchronised with the output sending a spike through a synchronisation
channel. This method gets the value where the output data should be cut in order to make
the output signal be synchronised with regard to the input signal.
Parameters
----------
read_data : np.array
Processed output data computed from the amplification value.
Returns
-------
int
Output cut value
"""
assert type(
read_data
) == np.ndarray, "read-data should be of type - numpy array"
cut_value = np.argmax(read_data[-1, :])
if read_data[-1, cut_value] < 0.05:
warnings.warn("initialize spike not recognised")
return cut_value
[docs]
def synchronise_output_data(self, read_data):
"""
The input signal is synchronised with the output sending a spike through a synchronisation
channel. All the data before the output reading instrument receives the spike is discarded.
This method cuts the output data in order to make the input signal be synchronised with the
output signal.
Parameters
----------
read_data : np.array
processed output data computed from the amplification value
Returns
-------
np.array
synchronized output data
bool
Whether if the cut value is zero
"""
assert type(
read_data
) == np.ndarray, "read-data should be of type - numpy array"
cut_value = self.get_output_cut_value(read_data)
# Add check that the cut_value is not 0
return read_data[:-1, cut_value:self.original_shape +
cut_value], cut_value == 0